Suflex® Astra® 703/105
Suflex® Astra® 703/105 is a general purpose, high heat-resistant, extruded polyvinylchloride plastic tubing designed for continuous use in 105°C applications. This material is rated UL VW-1 rated. Suflex® Astra® 703/105 is supplied in continuous lengths on spools.
Features
- VW-1 Flame Rating
- Extremely flexible. Does not crack with 180° bends
- -35°C brittle point
Download Suflex® Astra® 703/105 Datasheet
Product Specifications
Property | Mil-I-631 Grade C Requirements Conditioning | Mil-I-631 Grade C Requirements Requirements | Typical Astra® 703/105 Performance |
Dielectric Strength - Dry | C-96/23/50 | Min. 800 V/mil | 1180 V/mil |
Lengthwise Shrinkage | 2 h 130°C | 10% Max | 5% |
Softening Temperature | None | Min. 70°C | 100°C |
Flexibility | 200 h @ 100°C | No Cracks 180°C bend around 1/8" rod | No Cracking, proper return to round cross section |
Cold Performance | 50% Brittle Temp. Impact Method | Max -10°C | No Cracks at -25°C -35°C Brittle Point |
Corrosion | 720 h 70°C High Humidity | No Corrosion Max. 2% resistance increase of conductor | Conforms at 0.8% Resistance Increase |
Oil Resistance | High Swelling in Oil h 50°C | No Cracks, no oil penetration Max. 10° increase in dia. | Conforms 0.5% Increase |
Suggested Application
Suflex® Astra® 703/105 tubing is widely used on transformer, motor and coil lead wires. It also finds applications in electronic apparatus and in consumer goods such as toys, blenders, food machines, outboard motors, lawn care equipment, stereos, lighting equipment, motorcycles, etc. Suflex® Astra® 703/105 tubing may also be used for vacuum or pressure hoses and transfer of compatible liquids.DISCLAIMER
The suggested application is provided by Atkins & Pearce merely as an additional tool to assist the customer in making an appropriate electrical sleeving and tubing selection. This is only provided to serve as suggestions of electrical sleeving and tubing that may be appropriate based on certain criteria and should not be relied upon as determinative or as a substitute for customer testing.
Many variables exist in an electrical sleeving or tubing’s flexibilities, resistances, and treatment. Final electrical product selection should always be confirmed through the customer’s own testing process to determine if a particular product is the correct choice for a particular system. Atkins & Pearce is not responsible for selections made by the customer using any of the reference material provided. For optimal performance in specific systems, we strongly recommend that customers conduct exhaustive electrical tests in their own lab and consider retaining samples for their future internal reference. The importance of electrical product testing and data validation cannot be overstated.
As the customer, you and your company are responsible for appropriately testing all Atkins & Pearce electrical sleeving and/or tubing used in your application and for making the final selection based upon meeting appropriate safety and electrical standards. Atkins & Pearce makes no representation or warranty, expressed or implied, at law or in equity, in respect of the information provided, including, without limitation, with respect to merchantability or fitness for any particular purpose, which representations or warranties are hereby expressly disclaimed.